Extended-range measurement without contacting the medium

The Endress+Hauser Prosonic FMU44 is a cost-effective ultrasonic transmitter for sophisticated, continuous level measurement in liquids and bulk solids. It measures liquids up to 20 m and bulk solids up to 10 m, making it well suited to tall tanks, large silos, stockpiles and open-channel duties.

FMU44 can be used in storage tanks, vessels with agitators, stockpiles and conveyor-belt applications. It is also suitable for flow measurement in open channels and at weirs. The envelope curve is visible on the local display, while a 32-point linearization function supports level, volume and flow-rate conversion.

Why Choose the Prosonic FMU44?

Extended measuring range
Measures liquids up to 20 m and bulk solids up to 10 m for demanding tanks, silos and channels.
Durable non-contact sensing
The hermetically sealed, potted PVDF sensor does not contact the product, reducing wear and maintenance.
Straightforward commissioning
A four-line display, seven menu languages and envelope-curve visualization simplify setup and diagnostics.

How Ultrasonic Measurement Works

The sensor sends ultrasonic pulses toward the material surface and receives the returning echoes. The transmitter uses the measured time of flight to determine distance and calculate level. An integrated temperature sensor automatically compensates for temperature-related changes in the speed of sound.

Prosonic FMU44 Key Specifications

ParameterPublished specification
Measuring principleUltrasonic time-of-flight
Maximum measuring distanceLiquids: 20 m (66 ft); solids: 10 m (33 ft)
Blocking distance0.5 m (1.9 ft)
Accuracy±4 mm or ±0.2% of the set measuring range
Process temperature−40 to +80 °C (−40 to +176 °F)
Process pressure0.7 to 2.5 bar absolute (10 to 36 psi)
Main wetted materialPVDF
Process connectionFlange

Specifications, output variants and approvals depend on the selected order code. Confirm the current manufacturer documentation and complete application conditions before ordering.

Typical Applications

  • Water and wastewater tanks
  • Chemical storage and process vessels
  • Liquids, pastes and slurries within the published limits
  • Large silos and coarse bulk-material storage
  • Stockpiles and conveyor-belt monitoring
  • Open-channel and weir flow measurement

FMU42 or FMU44?

ModelMaximum rangeBlocking distance
Prosonic FMU42Liquids 10 m; solids 5 m0.4 m
Prosonic FMU44Liquids 20 m; solids 10 m0.5 m

Installation and Selection Notes

Provide a clear acoustic path between the sensor and product surface. Keep the filling stream, ladders, heating coils and structural members outside the ultrasonic beam. The maximum level must remain outside the 0.5 m blocking distance. Heavy foam, dense vapor, strong turbulence, vacuum and severe temperature gradients can weaken the echo and should be reviewed during selection.

Information Needed for Correct Selection

  1. Medium name and whether it is liquid, paste or bulk solid
  2. Tank or silo height and required measuring range
  3. Process temperature and absolute pressure
  4. Foam, vapor, dust, agitation and filling conditions
  5. Nozzle size, mounting position and internal obstacles
  6. Hazardous-area approval, power supply and signal requirements