Product News

Endress+Hauser Prosonic FMU40: Compact Ultrasonic Level Measurement for Liquids and Bulk Solids

News October 12, 2026

Endress+Hauser Prosonic FMU40: Compact Ultrasonic Level Measurement for Liquids and Bulk Solids

Endress+Hauser Prosonic FMU40 ultrasonic level transmitter supply

Reliable measurement without contacting the product

The Endress+Hauser Prosonic FMU40 is a compact ultrasonic transmitter for continuous, non-contact measurement of liquids, pastes and coarse bulk solids. It is also suitable for flow measurement in open channels and at weirs.

For operators who need a cost-effective instrument with straightforward commissioning, FMU40 combines an ultrasonic sensor, transmitter and local display in one compact device. Typical duties include storage tanks, vessels with agitators, stockpiles, conveyor belts and water or wastewater channels.

Why Choose the Prosonic FMU40?

Non-contact operation
The sensor does not touch the medium, helping reduce wear and maintenance in many tank and solids applications.
Simple commissioning
Menu-guided local operation, a four-line display and visible envelope curves support setup and diagnostics.
Versatile measurement
Continuous level, volume and open-channel flow can be handled with a 32-point linearization function.

How Ultrasonic Level Measurement Works

The sensor sends ultrasonic pulses toward the product surface and receives the reflected echoes. The transmitter determines the distance from the measured time of flight, then calculates level from the configured empty distance. An integrated temperature sensor automatically compensates for temperature-related changes in the speed of sound.

Prosonic FMU40 Key Specifications

ParameterPublished specification
Measuring principleUltrasonic time-of-flight
Maximum measuring distanceLiquids: 5 m (16 ft); solids: 2 m (6.6 ft)
Blocking distance0.25 m (0.8 ft)
Accuracy±2 mm or ±0.2% of the set measuring range
Process temperature−40 to +80 °C (−40 to +176 °F)
Process pressure0.7 to 3 bar absolute (10 to 44 psi)
Main wetted materialPVDF
Communication2-wire HART
Process connectionThread

Specifications and approvals depend on the selected order code. Confirm the current manufacturer documentation, medium conditions and installation geometry before ordering.

Typical Applications

  • Water, wastewater and utility tanks
  • Chemical storage and process vessels
  • Liquids, pastes and slurries within the published application limits
  • Small silos containing coarse bulk materials
  • Stockpiles and conveyor-belt monitoring
  • Open channels and weirs for flow measurement

Installation Points That Matter

Mount the sensor so the ultrasonic beam has a clear path to the product surface. Avoid filling streams, ladders, heating coils and other internal structures that can create false echoes. Keep the maximum product level outside the 0.25 m blocking distance. In vessels with agitators or irregular surfaces, use the envelope-curve display and false-echo mapping during commissioning.

Selection note: Ultrasonic measurement depends on a clear acoustic path. Heavy foam, dense vapor, strong turbulence, vacuum or extreme temperature gradients can weaken the echo. Share complete process and vessel details before final selection.

Information Needed for Correct Selection

  1. Medium name and whether it is a liquid, paste or bulk solid
  2. Tank or silo height and required measuring range
  3. Process temperature and absolute pressure
  4. Foam, vapor, dust, agitation and filling conditions
  5. Nozzle size, mounting position and internal obstacles
  6. Hazardous-area approval, power supply and signal requirements

Contact Us for FMU40 Selection and Quotation

HONGKONG XIEYUAN TECH CO., LIMITED

Email: becky@hkxytech.com
Web: www.hkxytech.com
Mobile: +86-15972186287 (WhatsApp & WeChat)

Technical reference: Endress+Hauser Prosonic FMU40 official product information. Product specifications and availability may change; confirm the complete order code before purchasing.