Product News

E+H FMR10B FMR10B-AAAADTBMWDGWEEB 80 GHz Radar Level Sensor

News September 14, 2026
Product News · Application Engineer Brief

E+H Micropilot FMR10B: Specify the Complete Order Code Before You Buy

Featured configuration: FMR10B-AAAADTBMWDGWEEB · 80 GHz non-contact radar level measurement for basic liquid and solid applications.

E+H FMR10B FMR10B-AAAADTBMWDGWEEB 80 GHz radar level sensor supplier
becky@hkxytech.com
+86 15972186287
Quick answer for procurement teams: We supply E+H FMR10B and the wider Endress+Hauser level measurement family for international projects. To receive an accurate quotation, send the complete order code—not only “FMR10B”—together with quantity and application details. Price, lead time and configuration are reconfirmed for every inquiry.

Why FMR10B Is Frequently Specified

The E+H Micropilot FMR10B is a compact free-space radar level instrument using 80 GHz technology. It provides continuous, non-contact measurement up to 10 m (33 ft) in basic liquid and solid applications. Typical duties include open basins, river monitoring, storage tanks, silos and stockpiles.

Engineering itemFMR10B reference
Measurement principle80 GHz free-space radar, non-contact
Maximum measuring rangeUp to 10 m / 33 ft
Reference accuracyLiquids ±5 mm; solids ±10 mm
Process temperature-40 to +60 °C
Process pressure-1 to 3 bar
Wetted materialsPVDF, PBT/PC

Senior Engineer’s Warning: “FMR10B” Is Not a Complete Purchase Description

A product family name identifies the measuring principle, but it does not fully define process connection, electrical output, approvals, housing, accessories or project-specific options. A one-character difference can change the supplied instrument. For this article, the complete example is:

FMR10B-AAAADTBMWDGWEEB

Please copy the full order code from the nameplate, datasheet or approved material list. If the existing unit is being replaced, also provide clear nameplate photos and the application conditions so we can check compatibility before quotation.

Five Installation Problems to Eliminate Before Commissioning

  1. Nozzle geometry: confirm nozzle height and diameter so the antenna has a clear view of the product surface.

  2. False echoes: avoid ladders, filling streams, heating coils and structural steel inside the radar beam.

  3. Wall proximity: do not select a mounting point merely because it is easy to reach; check the vessel geometry first.

  4. Condensation or buildup: review vapor, foam, dust and deposits that can affect the measurement environment.

  5. Incomplete RFQ data: never assume the family name alone defines the required output, approval or connection.

What to Send for a Fast, Accurate Quotation

  • Complete model and order code, for example FMR10B-AAAADTBMWDGWEEB

  • Required quantity and delivery country

  • Liquid or solid medium, measuring range and vessel geometry

  • Process temperature, pressure and process connection

  • Required signal/output, power supply, communication and approvals

  • Target delivery date and whether the request is for a new project or replacement

Hot-Selling E+H Level Measurement Models

All models below are currently receiving strong inquiry activity. Always quote the full configuration code shown on your requirement, because suffixes, lengths and options matter.

FamilyComplete inquiry example
FMR43FMR43-AABADFNX1X2JGFC+TC
FMR20BFMR20B-AABADTBMVCGVEEB
FMR10BFMR10B-AAAADTBMWDGWEEB
FMR30BFMR30B-AABAKHBMXQ0VEE3
FMR67FMR67B-AABAFBCJGPEBESJD1+EH
FMR62FMR62-NBBCAAGMF5MRK
FMR60FMR60-AAALAAGAA3XJG
FWR30FWR30-AA1B1B7B0+PC
FMR20FMR20-AAABNWDEXR01
FMR10FMR10-AAQBMWDEWFE2
NMR84NMR84-IC1BB1C2B1ACABFB1AHJITD
NMR81NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3
FMR67BFMR67B-AABAENAFGAJCRBFD3
FMR66BFMR66B-AABAEDAHBSI1WFEA
FMR62BFMR62B-AABACAAJGNEBEUKB+AA
FMR60BFMR60B-AABAEJAFBSJCRCFA+LA
FMR54FMR54-AAACCABDD1AJJ+AAEHJALA
FMR52FMR52-BCACCBBPAGK+AA
FMR51FMR51-BBACCABCA5AGJ
FMP50FMP50-BCACCBAAA1GDJ+AAF371,2M
FMP51FMP51-BAACCABCB3ARJ+AA, 7000MM
FMP52FMP52-AAACCAOACHK+AAIJZ1 (2050MM)
FMP53FMP53-AAACCADAB5TDJ L=560 mm
FMP54FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM)
FMP55FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM
FMP56FMP56-AAAAAALAABGDE
FMP57FMP57-AAACCAAEA4GGE (2000mm)
FMU40FMU40-ARB2A2
FMU41FMU41-1NB2A2
FMU42FMU42-AVB2A42A
FMU44FMU44-ATB2A23A
FMU30FMU30-AAHEAAGGF
FMG50FMG50-AABADJACA

And other E+H level measurement products are available on request. Send the complete order code for technical and commercial checking.

Frequently Asked Questions

Can I request a quotation with only “FMR10B”?
You can start the conversation with the family name, but a firm quotation requires the complete configuration code and quantity.

Is FMR10B suitable for both liquids and solids?
Yes, it is designed for basic continuous non-contact level measurement in liquid and solid applications, subject to application review.

Can you quote discontinued or replacement E+H level instruments?
Send the full old order code, nameplate photo and process data. We will check the requested item and suitable current alternatives where applicable.

Request a quotation

E+H FMR10B and Level Measurement Products

Include the complete model, quantity and destination country.

becky@hkxytech.com
+86 15972186287

Technical values are reference data for the E+H Micropilot FMR10B family. Final suitability, exact configuration, approvals, price and delivery must be confirmed against the complete order code and application conditions.