Endress+Hauser Liquiline CM444-AAM4CA3FF11BAA+NS: Expandable Four-Channel Multiparameter Transmitter
Endress+Hauser Liquiline CM444-AAM4CA3FF11BAA+NS: Expandable Four-Channel Multiparameter Transmitter

Four-channel flexibility for modern liquid-analysis systems
The Endress+Hauser Liquiline CM444-AAM4CA3FF11BAA+NS belongs to the CM444 family of modular four-wire multiparameter transmitters. It supports up to four Memosens sensors in any combination and can be extended for a wide range of water, process and utility applications.
Liquiline CM444 enables operators to standardize several analytical measuring points on one transmitter platform. Automatic sensor recognition, hot plug-and-play operation and a common user interface help reduce commissioning time. Modular inputs, outputs, relays, controllers and mathematical functions also allow the transmitter to operate cleaning systems or dosing pumps when suitably configured.
The complete code identifies a configured device. Use the full code when requesting a quotation or replacement. Exact installed inputs, outputs, communication interfaces, power supply, modules and approvals must be verified from the nameplate, order documentation and current manufacturer configuration data.
Why Choose Liquiline CM444?
Combine different analytical parameters on one field transmitter and simplify plant-wide standardization.
Add channels, outputs, relays or supported communication functions as plant requirements evolve.
Diagnostics and verification functions support status-oriented maintenance and improved measuring-point availability.
Measurement Possibilities
| Measurement group | Typical parameters | Typical objective |
|---|---|---|
| Electrochemical | pH, ORP/redox, conductivity, dissolved oxygen | Quality, concentration and process control |
| Disinfection | Chlorine and other disinfectant parameters | Dosing control and residual monitoring |
| Optical / solids | Turbidity, sludge level, SAC, nitrate | Water and wastewater process monitoring |
Liquiline CM444 Key Specifications
| Parameter | CM444 family specification |
|---|---|
| Controller type | Modular four-wire multiparameter field transmitter |
| Digital sensor inputs | 1 to 4 Memosens inputs; sensors connectable in any combination |
| Optional additional inputs | Up to 2 × 0/4–20 mA and 2 to 4 digital inputs, version dependent |
| Current outputs | 2 to 8 × 0/4–20 mA, configuration dependent |
| Relay functions | Alarm relay plus up to four relays, configuration dependent |
| Communication | 0/4–20 mA, HART, PROFIBUS DP, Modbus RTU/TCP, EtherNet/IP, PROFINET and web server, version dependent |
| Ingress protection | IP66 / IP67 |
These values describe the Liquiline CM444 platform. Confirm which functions are installed in CM444-AAM4CA3FF11BAA+NS before purchasing or replacing an existing unit.
Typical Industries and Applications
Municipal and industrial water and wastewater treatment
Food and beverage process and cleaning applications
Life-science water-quality monitoring
Power and energy water/steam-cycle systems
Chemical production and industrial utilities
Marine and general process-industry applications
Selection and Replacement Checklist
Match the complete order code and confirm every connected sensor, measured parameter, channel count, analog output, relay, fieldbus protocol, power supply, cable entry and approval. For retrofit work, also check the existing I/O modules, wiring and control-system requirements.
Information Needed for a Quotation
Complete order code: CM444-AAM4CA3FF11BAA+NS
Photo of the transmitter nameplate and connected sensor labels
Measured parameters and required number of channels
Required outputs, relays and communication protocol
Power supply, cable-entry and approval requirements
Destination country and required quantity
Contact Us for CM444-AAM4CA3FF11BAA+NS Availability and Quotation
HONGKONG XIEYUAN TECH CO., LIMITED
Email: becky@hkxytech.com
Web: www.hkxytech.com
Mobile: +86-15972186287 (WhatsApp & WeChat)
Technical reference: Endress+Hauser Liquiline CM444 official product information and current Liquiline CM442/CM444/CM448 Technical Information. Product specifications and availability may change; confirm the complete order code before purchasing.
Latest News
-
Endress+Hauser Liquiline CM448-AA36A31AABAA+AA: High-Capacity Eight-Channel Multiparameter Transmitter…
October
28, 2026
-
Endress+Hauser Liquiline CM444-AAM4CA3FF11BAA+NS: Expandable Four-Channel Multiparameter Transmitter…
October
27, 2026
-
Endress+Hauser Liquiline CM442-AAM1A1F010A+AA: Flexible Two-Channel Multiparameter Transmitter…
October
26, 2026
-
Endress+Hauser Liquiline M CM42-MAA011EAF00: Robust Two-Wire Transmitter for Liquid Analysis…
October
23, 2026
-
Endress+Hauser Liquiline CM14: Compact Memosens Transmitter for Liquid Analysis
October
22, 2026
-
Endress+Hauser Gammapilot FMG50: Non-Contact Radiometric Measurement for Extreme Process Conditions…
October
21, 2026
-
Siemens FY27 Electrical Product Price Adjustment: Planning Ahead for Industrial Purchases…
October
20, 2026
-
Endress+Hauser Prosonic FMU30: Compact Ultrasonic Level Measurement up to 8 Meters…
October
20, 2026
-
Endress+Hauser Prosonic FMU44: Long-Range Ultrasonic Level Measurement up to 20 Meters…
October
19, 2026
-
Endress+Hauser Prosonic FMU42: Non-Contact Ultrasonic Level Measurement up to 10 Meters…
October
16, 2026