Original Yokogawa VP200-AM32/JF3/LV/GM Current-to-Pneumatic Positioner VP200-AM32/JF3/LV/GM Control Valve In Stock
Original Yokogawa VP200-AM32/JF3/LV/GM Current-to-Pneumatic Positioner VP200-AM32/JF3/LV/GM Control Valve In Stock

CONTACT INFORMATION:
HONGKONG XIEYUAN TECH CO., LIMITED
M: 86-15972186287 (WhatsApp &Wechat)
Skype: live:add9ccbc92a03c65
Email: becky@hkxytech.com
Sales Manager: Becky Luo
OUR PRODUCTS
Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
OUR ADVANTAGE BRANDS
Siemens, Honeywell,Allen Bradley, ABB, Schneider, Pepperl+Fuchs, MTL, Yokogawa, Mitsubishi, Omron, Wago, Pilz,Phoenix Contact,Sick, SMC, Norgren,Festo, IFM, Weidmuller, Rosemount, Hirschmann, Moxa, Emerson,Fluke, Endress+Hauser, Rittal and so on.
■ FEATURES
Model VP200 Current-to-Pneumatic Valve Positioner
converts 4 to 20 mA DC or 10 to 50 mA DC signal to
a pneumatic signal for control valve actuation.
A valve-stem-position feedback mechanism is provided. This positioner minimizes transmission lag,
improves valve characteristics and response, and
reduces flow-pressure variation effect.
■ STANDARD SPECIFICATIONS
Applicable Control Valve:
Diaphragm Actuator, Single acting Cylinder, and
Double acting Cylinder.
Materials:
Case: Aluminum die-cast
Paint: Polyurethane resin-baked finish
Color: Deep-sea moss-green (Munsell 0.6GY3.l/2.0
or equivalent)
Pressure Gauge Case:
Stainless steel JIS SUS 304
Input Signals:
4 to 20 mA DC or 10 to 50 mA DC
Input Resistance:
250 to 310 (Input signal 4 to 20 mA DC)
80 to 105 (Input signal 10 to 50 mA DC)
Output signals and pressure gauge scale:
No gauge in standard. Pressure gauge can be
selected as option. The supply pressure unit on the
name plate for non-gauge model is Pa.
■ MODEL AND SUFFIX CODES
MODEL AND SUFFIX CODES Model Suffix Codes Description VP200 . . . . . . . . . . . . . . . . . . . . . . . . . . Input Signal -A . . . . . . . . . . . . . . . . . . . . . . . -B . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC 10 to 50 mA DC Applicable Control Valve L . . . . . . . . . . . . . . . . . . . . . Diaphragm Actuator: Direct output*1(small capacity, less than 0.5 l) Single Acting Cylinder: Direct output*1(small capacity, less than 0.5 l) Current-to-pneumatic positioner M . . . . . . . . . . . . . . . . . . . . . Diaphragm Actuator: Direct output*1 Single Acting Cylinder: Direct output*1 N . . . . . . . . . . . . . . . . . . . . . Double Acting Cylinder P . . . . . . . . . . . . . . . . . . . . . Diaphragm Actuator: Reverse output*2(small capacity, less than 0.5 l) Single Acting Cylinder: Reverse output*2(small capacity, less than 0.5 l) Q . . . . . . . . . . . . . . . . . . . . . Diaphragm Actuator: Reverse output*2 Single Acting Cylinder: Reverse output*2 Connections 1 . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . . Air Connections: Rc1/4, Electrical Connection: G1/2 female Air Connections: Rc1/4, Electrical Connection: G3/4 female Air Connections: 1/4NPT female, Electrical Connection: 1/2NPT female Air Connections: 1/4NPT female, Electrical Connection: 3/4NPT female Operating Temperature Limits 1 . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . -10 to 80C -30 to 40C Optional Codes /JF3 . . . . . . . . /G11 . . . . . . . . /JS1 . . . . . . . . /SCF- . . . . . /A1 . . . . . . . . . /X1 . . . . . . . . . /SS . . . . . . . . . /GP. . . . . . . . . /GM . . . . . . . . /GB . . . . . . . . /GE . . . . . . . . /GW . . . . . . . . /NM . . . . . . . . /NB. . . . . . . . . /NE. . . . . . . . . /LV . . . . . . . . . /M1 . . . . . . . . TIIS Flameproof type. Apply to connections code 1, 2 and 3.*4 Packing adapter for TIIS Flameproof Electrical connection: G 1/2 female, Applicable cable O.D.: 8 to 12 mm /G21 Packing adapter for TIIS Flameproof . . . . . . . . Electrical connection: G 3/4 female, Applicable cable O.D.: 10 to 16 mm TIIS Intrinsically safe type. Apply to only input signal code-A.*3 Special Color Finished or Positioner Color High pressure gauge for diaphragm-actuator or single acting cylinder. 1 MPa, 10 kgf/cm2, 10 bar, 150 psi Epoxy resin-baked coating, not applicable for SCF- External screw material is SUS304 stainless steal. With pressure gauge. Pa calibration With pressure gauge. kgf/cm2 calibration With pressure gauge. bar calibration With pressure gauge. psi calibration With Double scale pressure gauge. Scale unit: Pa/kgf/cm2 Without pressure gauge. Supply pressure unit: kgf/cm2 Without pressure gauge. Supply pressure unit: bar Without pressure gauge. Supply pressure unit: psi With two levers (long and short) With lever (for Motoyama 3800 series valve)
More Models:
We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
Contact:
Latest News
-
Endress+Hauser Liquiline CM442R-75V4/0: Compact Two-Channel DIN-Rail Multiparameter Transmitter…
October
29, 2026
-
Endress+Hauser Liquiline CM448-AA36A31AABAA+AA: High-Capacity Eight-Channel Multiparameter Transmitter…
October
28, 2026
-
Endress+Hauser Liquiline CM444-AAM4CA3FF11BAA+NS: Expandable Four-Channel Multiparameter Transmitter…
October
27, 2026
-
Endress+Hauser Liquiline CM442-AAM1A1F010A+AA: Flexible Two-Channel Multiparameter Transmitter…
October
26, 2026
-
Endress+Hauser Liquiline M CM42-MAA011EAF00: Robust Two-Wire Transmitter for Liquid Analysis…
October
23, 2026
-
Endress+Hauser Liquiline CM14: Compact Memosens Transmitter for Liquid Analysis
October
22, 2026
-
Endress+Hauser Gammapilot FMG50: Non-Contact Radiometric Measurement for Extreme Process Conditions…
October
21, 2026
-
Siemens FY27 Electrical Product Price Adjustment: Planning Ahead for Industrial Purchases…
October
20, 2026
-
Endress+Hauser Prosonic FMU30: Compact Ultrasonic Level Measurement up to 8 Meters…
October
20, 2026
-
Endress+Hauser Prosonic FMU44: Long-Range Ultrasonic Level Measurement up to 20 Meters…
October
19, 2026
